Categories > Families > Types > Products
Designed for a wide range of pre-hospital, hospital or primary care needs, the Welch Allyn PIC 40 provides everything needed for patient monitoring and defibrillating.
|
 |
|
The Welch Allyn PIC 40 is a combination vital signs monitor and defibrillator ready to deliver immediate performance wherever sudden cardiac arrest may strike.
The PIC 40 comes equipped with defibrillation capabilities, ECG monitoring, voice-memo, synchronized cardioversion, Nellcor SpO2, pacing, optional NIBP and optional data record and playback.
This breadth of options makes the Welch Allyn PIC 40 the first choice for multiple levels of emergency patient care. Ready for rescue, the versatile Welch Allyn PIC 40 provides dependable emergency/monitoring performance for both the first responder and advanced team. The instrument features an integrated Automated External Defibrillator (AED) for use by immediate care responders.
The PIC 40 is also upgradeable. Increasing your treatment potential and purchase value without increasing the physical size and weight of the unit.
Prices shown are for sales and shipment in the US only and are subject to change without notice.
International prices will vary significantly due to technical configuration and country-specific import charges,
levies, duties, sales taxes, and shipping costs. For pricing and customer service please contact LifeLine Medical Inc. at our toll free number displayed below.
Biphasic Manual defibrillation (2 - 360 joules) Synchronized cardioversion Automated External Defibrillation with escalating energy of 200/300/360 (voice and text prompts) Nellcor SpO2 External Pacing 6.5" color display High Performance Welch Allyn SuperPac rechargeable batteries using sophisticated NiMH technology Innovative design to allow for future upgrades Simple operation with dedicated treatment parameter controls
Optional Features NIBP Data record and playback
GENERAL Weight: 10.5 lbs (4.76 kg) basic configuration. Size: 16.7 x 12.5 x 5.3 inches; 41.75 x 32 x 13 cm. Operating: Time: 2 hours Temperature*: 0 to 45° C Humidity* (NC): 15 to 95% RH Vibration*: MIL-STD 810E Shock / Drop*: MIL-STD 810E Altitude: Up to 15,000 feet Transport and Storage: Temperature (-30 to 70˚C), humidity (15 to 95% non-condensing), atmospheric pressure ( 860 to 1060 hPa), shock/vibration (ISTA 1A) Enclosure Protection*: Solid Foreign Object: IEC 529, IP2X Water: IEC 529, IPX4. MONITOR/DISPLAY Input: 3-lead or 5-lead patient cable, paddles, or multipurpose hands-free adapter. Size: 6.4 inch (16.5 cm) diagonal, non-fade. Type: LCD color active matrix. Display Resolution: 640 x 480 pixels. Sweep Speed: 25 mm / sec. Lead Selections: Paddles (Pads), I, II, III, AVR, AVL, AVF, V. Frequency Response: (User-selectable). 2 to 20 Hz Limited mode 0.5 to 40 Hz Monitor mode 0.05 to 150 Hz Diagnostic mode(automatically sets chart recorder response) Common Mode Rejection: Complies with AAMI EC13- 1992 section 3.2.9.10. Heart Rate Meter: 20 to 300 BPM. Heart Rate Alarms: User-selectable. Size: 0.125, 0.25, 0.5, 1, 2, 4 cm/mv and auto-ranging. AED Configurable: Basic & Basic+ modes Operation: Continuous analysis of ECG advises shock on VFIB, shockable VTACH Energy Sequence: User configurable Biphasic: 150/200/300/360J Factory Default: Biphasic: 150/200/300J Prompts: Audible voice and visual text prompts DEFIBRILLATOR Waveform: Biphasic: Low current, impedance compensated, optimized terminating current, truncated exponential biphasic Energy Select: External: 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 J. Internal: 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 50 J. Charge Time: < 10 seconds @ 360 J (typical) SuperPak Output: Adult paddles, internal paddles, peds adapter and multipurpose hands-free adapter available. Synchronizer: Delivers energy within 60 msec. Disarm: Front panel switch. RECORDER Type: High-resolution thermal array. Annotation: Time, date, ECG lead, ECG gain, heart rate, defibrillation and pacing parameters and treatment summary ACLS events. Paper Width: 50 mm. Paper Speed: 25 mm/sec. Delay: 6 seconds. Frequency Response: Automatically set to monitor's frequency response. Tx Summary Log: 60 ECG events or 300 non-ECG events. BATTERY High Capacity Type: NiMH 12 volt - Welch Allyn SuperPac. Low Battery Indicator: Flashing low battery icon on display. Multiple Paired Contacts: Ensures quick, error-free insertion and backup reliability. Recharge Rate: 80% in 7.5 hours, 100% in 9.5 hours. (For high capacity batteries) PULSE OXIMETER Measurement Range: 31 to 99%. Heart Rate Range: 30 to 250 BPM ±5% or 5 BPM whichever is less. Accuracy: 81-99% = ±2%, 70-80% = 3%, 0-69% unspecified Update Period: Every pulse after 4 valid pulses Alarm Limits: 60 lower limit, 70 upper limit to 99% Probe: Reusable finger or multi-site probe
For additional product information, please see Sell Sheet under Additional Documentation.
To view PDF documents, you need the free Adobe Acrobat Reader. If you do not already have it, you can download and install it directly from the Adobe website. When you are done with the PDF file, close the PDF window to return to this page.
Click each checkbox to select the accessories you want before adding to your Wish List.
|