|
Categories > Families > Types > Products
The Welch Allyn PIC 50 system, is the most innovative, reliable monitor/defibrillator/pacer available.
Intelligently designed for the user, the Welch Allyn PIC 50's controls and menus are easy-to-use. Welch Allyn's innovative platform makes it possible for upgrades to be performed at anytime.
The PIC 50 is also upgradeable. Increasing your treatment potential and purchase value without increasing the physical size and weight of the unit. This product comes with multiple configurations. Please contact us to find the product that best suits your needs.
Prices shown are for sales and shipment in the US only and are subject to change without notice.
International prices will vary significantly due to technical configuration and country-specific import charges,
levies, duties, sales taxes, and shipping costs. For pricing and customer service please contact Lifeline Medical Inc. at our toll free number displayed below.
The lightest defibrillator (10 lbs) with the most monitoring options available. Rugged transport unit designed for both out-of-hospital critical care and hospital users. Very simple operation with dedicated controls for monitor, defib, pacing and treatment summary. Innovative design to allow custom configurations and future upgrades as needs change.
Standard ECG Defib Resp SpO2
Options 12-LEAD with interpretation PACER AED NIBP 2 x IBP TEMP CO2 Sophisticated Communication Options
DEFIBRILLATOR Waveform: Biphasic: Low current, impedance compensated, optimized terminating current, truncated exponential biphasic Energy Select: External: 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 J. Internal: 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 50 J. Charge Time: < 10 seconds @ 360 J (typical) Charge Indicator: Audible and graphic. Output: Adult paddles, internal paddles, peds adapter and multipurpose hands-free adapter available. Synchronizer: Delivers energy within 60 msec. Disarm: Front panel switch. MONITOR/DISPLAY Input: 3-lead PIC: 3-lead or 5-lead patient cable, paddles, or multipurpose hands-free adapter. 12-lead PIC: 3-lead, 12-Lead patient cable, paddles or mutipurpose hands free adapter. Size: 6.5inch; 16.5cm diagonal, non-fade. Type: Color active matrix TFT display Display Resolution: 640 x 480 pixels. Sweep Speed: 25 mm / sec. Lead Selections: Paddles (Pads), I, II, III, AVR, AVL, AVF, V. Frequency Response: (User-selectable). 2 to 20 Hz Limited mode 1 to 40 Hz Monitor mode 0.05 to 40 Hz Limited Diagnostic mode 0.05 to 150 Hz Diagnostic mode (automatically sets chart recorder response) Common Mode Rejection: 90dB (Complies with AAMI EC13-1992 section 3.2.9.10.) Heart Rate Meter: 20 to 300 BPM. Heart Rate Alarms: User-selectable. Size: 0.125, 0.25, 0.5, 1, 2, 4 cm/mv and auto-sizing. ECG Output: 1 V/mV RECORDER Type: High-resolution thermal array. Annotation: Time, date, ECG lead, ECG gain, heart rate, defibrillation and pacing parameters and treatment summary ACLS events. Paper Width: 50 mm. Paper Speed: 25 mm/sec. Delay: 6 seconds. Frequency Response: Automatically set to monitor's frequency response. Treatment Summary: 7 switches to record key ACLS events (IV, INTUB, EPI, LIDO, ATROP, etc.). Automatically logs into memory the type of event, time and ECG sample. Tx Summary Log: 60 ECG events or 4000 non-ECG events. BATTERY High Capacity Type: NiMH 12 volt - Welch Allyn SuperPac. Low Battery Indicator: Flashing low battery icon on display. Multiple Paired Contacts: Ensures quick, error-free insertion and backup reliability. Recharge Rate: 80% in 7.5 hours, 100% in 9.5 hours. (For high capacity batteries) GENERAL Weight: 10 lbs; 4.5 kg (basic configuration). Size: 12.5 x 12.5 x 5.3 inches; 32 x 32 x 13 cm Operating: 2.0 hours of continous ECG, SPO2, CO2, and BP monitoring or 120 shocks at 360Joules (typical) Actual operating times will vary according to the condition of the battery and the number of additional options activated. Temperature*: 0 to 45° C Humidity* (NC): 15 to 95% RH Vibration*: MIL-STD 810E Shock / Drop*: MIL-STD 810E Altitude: Up to 15,000 feet Transport and Storage: Temperature (-30 to 70˚C), humidity (15 to 95% non-condensing), atmospheric pressure ( 860 to 1060 hPa), shock/vibration (ISTA 1A) Enclosure Protection*: Solid Foreign Object: IEC 529, IP2X Water: IEC 529, IPX4. * All tests performed per AAMI DF-2 Defibrillation Standard. PULSE OXIMETER Measurement Range: 31 to 99% Heart Rate Range: 30 to 250 BPM ±5% or 5 BPM whichever is less. Accuracy: 81-99% = ±2%, 70-80% = 3%, 0-69% unspecified. Update Period: Every pulse after 4 valid pulses. Alarm Limits: 60 lower limit, 70 upper limit to 99%.
For additional product information, please see Sell Sheet under Additional Documentation.
CERTIFICATION North American certification: UL and cUL.
To view PDF documents, you need the free Adobe Acrobat Reader. If you do not already have it, you can download and install it directly from the Adobe website. When you are done with the PDF file, close the PDF window to return to this page.
Click each checkbox to select the accessories you want before adding to your Wish List.
|